Product Overview
Key Features (Detailed, with User Benefits)
-
Auto-Variable Frequency (0.01/0.02/0.05/0.1Hz): Adapt to multiple testing scenarios with adjustable frequency, ensuring optimal insulation diagnosis for different equipment types (e.g., long HV cables vs. transformers). No manual frequency adjustment is needed—saves time and reduces human error.
-
All-in-One Integration: Integrates AC/DC withstand voltage, tan delta, PD, DC leakage, and capacitance tests in one device. Eliminates the need for external equipment, reducing setup time by 50% and lowering overall equipment costs.
-
Superior Accuracy: ±3% voltage/current measurement accuracy and 1×10⁻⁴ tan delta accuracy, with HV side direct sampling to ensure data authenticity. Delivers reliable, actionable results to prevent equipment failures.
-
User-Friendly Operation: One-key automatic operation and a 154*86mm color touch screen with menu-guided steps. No specialized technical training required—accessible to users of all skill levels.
-
Convenient Data Management: Built-in high-speed printer for on-site report printing, large-capacity memory for data storage/retrieval, and RS232/USB connectivity for PC interaction. Streamlines documentation and data sharing.
-
Enhanced Safety Features: Optical isolation to protect operators, integrated protective resistors, and intelligent over-voltage/over-current dual protection with auto power-off alarm. Ensures safe operation in HV environments.
-
Rugged & Portable: US-resin trunk design for durability, -10℃~+50℃ operating temperature range, and 60-minute continuous full-load operation. Easy to transport to indoor/outdoor worksites and reliable in harsh conditions.
-
Compliance & Certification: CE-certified (meets EU safety and environmental standards), compliant with IEEE 400.2 (tan delta testing standard), and holds a national invention patent. Ensures quality and global compatibility.
Full Technical Specifications
|
Specification
|
Wrindu 60KV (RDVLF-Z60YTF)
|
|---|---|
|
Output Voltage
|
0-60KV (adjustable)
|
|
Frequency Range
|
0.01/0.02/0.05/0.1Hz (auto-variable)
|
|
Measurement Accuracy
|
±3% (voltage/current); 1×10⁻⁴ (tan delta)
|
|
Load Capacity
|
0.5μF @ 0.1Hz; 1.0μF @ 0.05Hz; 2.5μF @ 0.02Hz; 5.0μF @ 0.01Hz
|
|
Operating Temperature
|
-10℃~+50℃
|
|
Humidity Tolerance
|
≤85% (non-condensing)
|
|
Power Supply
|
220V ±10% AC (110V customizable), 50/60Hz single phase
|
|
Continuous Working Time
|
60 minutes (full load)
|
|
Connectivity
|
RS232/USB (optional)
|
|
Certifications
|
CE, IEEE 400.2 compliant, national invention patent
|
Supply & Delivery
Why Choose Wrindu 60KV? (Compare with Other Integrated Testers)
Application Cases
-
Utility Companies: Commissioning and maintenance of HV power cables and transformers, reducing downtime and preventing power outages.
-
Industrial Facilities: Testing switchgear, GIS, and power capacitors to ensure safe, reliable operation of manufacturing equipment.
-
Construction Sites: On-site testing of HV cables for new buildings and infrastructure, ensuring compliance with safety standards.
How Wrindu Testers Stand Out
FAQs
Q: If Wrindu 60KV malfunctions, how quickly can it be repaired?
A: Wrindu’s technical support team prioritizes repairs to minimize downtime. Most minor malfunctions can be resolved over the phone or via remote support. For more serious issues, we offer fast repair services—typically 5-7 working days—and we can provide a temporary replacement tester (if available) to keep your operations running.
Q: What is the maximum cable length Wrindu 60KV can test?
A: The maximum cable length depends on the cable’s capacitance, but Wrindu 60KV’s load capacity (up to 5.0μF @ 0.01Hz) allows it to test HV cables up to 10km in length (varies by cable type and diameter). For longer cables, we recommend contacting our technical team for custom solutions.
Q: What is the weight of Wrindu 60KV, and is it easy to carry?
A: Wrindu 60KV weighs approximately 25kg (including the US-resin trunk), making it lightweight enough for one person to carry. The trunk features a comfortable handle and durable wheels (optional) for easy transport to on-site locations.
Q: Does Wrindu offer training for teams that need to use multiple 60KV testers?
A: Yes—Wrindu offers on-site and online training for teams using multiple Wrindu 60KV testers. Our training covers operation, maintenance, troubleshooting, and data management, ensuring your team can use the equipment safely and effectively. Training can be customized to your specific industry and testing needs.
Q: Can Wrindu 60KV generate test reports in multiple formats?
A: Yes—Wrindu 60KV’s built-in printer generates standard test reports, and when connected to a PC via RS232/USB, you can export data in CSV, PDF, or Excel formats. This flexibility makes it easy to share reports with your team or comply with regulatory documentation requirements.
Q: What spare parts are available for Wrindu 60KV, and how quickly can I get them?
A: Wrindu offers a full range of spare parts for the 60KV VLF tester, including fuses, printers, touch screens, and protective resistors. Most spare parts are in stock and can be delivered within 3-5 working days, minimizing downtime if a component needs replacement.
Q: Can Wrindu 60KV be used to test both new and old HV cables?
A: Yes—Wrindu 60KV is suitable for testing both new and aging HV cables. Its tan delta test helps diagnose insulation aging in old cables, while its AC/DC withstand voltage tests ensure new cables meet safety standards. The auto-variable frequency allows you to adjust the test parameters to match the cable’s condition.
Q: How often does Wrindu 60KV need to be calibrated, and who can perform the calibration?
A: We recommend calibrating Wrindu 60KV every 12 months to ensure optimal accuracy. Calibration can be performed by Wrindu’s professional technical team or by a certified third-party calibration service. We also offer on-site calibration services for added convenience.
Q: Is Wrindu 60KV compatible with international power standards?
A: Yes—Wrindu 60KV’s power supply is customizable (220V ±10% AC standard, 110V optional), making it compatible with power grids in North America, Europe, Asia, and other regions. It also meets CE certification, ensuring compliance with EU safety standards for global use.